LAVA or Ember panel will not heat.
- Verify 120v power to controller.
- Verify 120v at load wires of controller when controller is calling for heat.
- Verify 120v at connection to panel at junction box at rear of panel.
- Verify panel power switch is in the "ON" position (if equipped).
- LAVA internal temperature limiters may have actuated. Ā Turn off unit using "Power" switch on the panel and wait 30-60 minutes for unit to reset.
- Disconnect panel power line from the supplyĀ in the junction box and measure panel for correct ohms. Ā Verify Power Switch is "ON" (if equipped).
lava 250: Ā 48.4 Ohms
lava 500: Ā 25.3 Ohms
lava 750: Ā 17.15 Ohms
lava 1000: Ā 13.2 Ohms
Ember 600: Ā 23 Ohms
Ember 800: Ā 18 Ohms
Ā
If ohms values are 0, OL, INF or "open circuit". Ā Take reading in 30 minutes. Ā This will allow tripped limiters to reset. Ā If value is still "open", unit is defective. Ā