A common question we receive is “can you put radiant heat under vinyl flooring?” The answer is a resounding “yes” but of course you’ll want to select the right floor heating system for your project.
Our TempZone™ product line is the ideal match for under vinyl floor heating because each of the products are designed to be embedded within a layer of thinset or self-leveling cement. Not only does this process create exceptionally even heating throughout the room, but it also helps provide a flat surface that makes installation easier and prevents thinner vinyl flooring products from conforming to the shape of the heating wire when warm.
Take a look at our comprehensive Luxury Vinyl Flooring Design Guide and see how electric floor heating can easily be added to your LVT flooring project.
Provide us with a sketch of your room that includes dimensions and other relevant information, you’ll receive a free SmartPlan within one business day.
Electric in-floor heating systems generate an even heat throughout your home and will not disturb dust, reducing the chance of possible allergic reactions. What's more, radiant heated floors reduce noise levels and the amount of dry air in your home. There are other benefits to floor heating as well, including financial perks, as they are inexpensive to install and typically don't add more than a quarter to electric bills.
WarmlyYours provides free design services to make sure that customers purchase the heating system that best meets their project requirements. Depending on the floor type and the shape and size of a room's layout, the size and placement of heating mats will differ.
The floor heating systems are offered in both 120 volt and 240 volt for the North American market. A 208 volt breaker panel can also accommodate our 240 volt floor heating system. It is important to note that the energy consumption will be the same: a 240 volt system will not cost more to operate than a 120 volt system. You are billed in kilowatts, and the 120 volt and 240 volt systems use the same amount of kilowatts. WarmlyYours often specifies a 120 volt system in smaller projects while a 240 volt system is typically recommended for larger projects (120 square feet of electric floor heating coverage or more). The benefit of switching to a 240 volt system is the reduction in amperage. Our programmable thermostat can control a radiant floor system up to 15 amps. The 120 volt system will reach 15 amps at 120 square feet of electric floor heating coverage. However, the 240 volt system will reach 15 amps at 240 square feet of electric floor heating coverage, allowing a much larger system to be connected to the thermostat. For installations over 240 square feet, a relay contactor or power modules are needed.
The answer to this question will depend on a whole host of variables related to electric floor heating, including, but not limited to, the run time (for supplemental heating, we usually recommend between 4-8 hours per day), the electric radiant floor heating system you're using, the total square footage, and your local electrical cost. Typically, the cost is just a few cents a day.
To figure out how much electric floor heating might cost to run for you, make sure to use our interactive Operating Cost Calculator.
When WarmlyYours electric floor heating systems are being installed on a concrete slab, we strongly recommend adding a layer of insulation over the slab prior to installing the system. While our electric floor heating provides up to 25% more heating power per square foot than many of our competitors, the slab will always act as a "heat sink." Some of the heat that would otherwise be transferred to the flooring surface will remain in the slab, causing the floor’s surface temperature to be considerably lower. This is true with any electric radiant floor heating system.
When installed on top of a concrete slab without insulation, it is generally accepted that electric floor heating will take the chill away from the floor and provide a small amount of warmth. Adding insulation on top of the slab and beneath any electric radiant floor heating system will allow a greater percentage of the heat generated to transfer to the flooring surface. This results in greater efficiency and therefore faster warm up times, higher expected surface temperatures and lower energy usage. The floor will have the capacity to warm to a comfortable temperature, and in some cases can be employed as the primary heat source for that room.
The recommended types of insulation are natural cork, insulated tile backer boards and insulated underlayment, such as ThermalSheet™ synthetic cork.
Since most Luxury Vinyl Tile (LVT) manufacturer's set a maximum temperature for radiant floor heating, the system should have little to no effect on the rubber/cork backing.
Pre-attached backing can act as an insulating layer though, meaning it can prevent the radiant heating from efficiently directing heat up through the floor. Please check with the manufacturer for the r-value of the product. Look for an assembled plank with an r-value of less than 1. The lower the r-value, the better!
Yes, in most cases, an electric floor heating system can be effective as a primary heat source. However, our TempZone™ and Environ™ systems are most commonly used as a secondary heat source, providing floor-to-ceiling radiant heat to any room in your home where you desire more warmth and comfort.
If you are considering electric floor heating for an addition to your home, such as a sunroom where you have no other source of heat, WarmlyYours offers an innovative online tool which calculates approximate heat loss. This tool can help you to determine if a WarmlyYours’ electric radiant floor heating system will provide your desired comfort temperature throughout the year. You can access the Heat Loss Calculator or you can call us at (800) 875-5285 and a Customer Service Representative will make the calculation for you.
Supplemental heat can be addressed by changing the spacing on cable installs. Floor location in the house is very important when considering adding supplemental heating to a floor. For example: If heating a second story floor, over a heated space, cable at 4" spacing can be used. The same type of heating over an unheated space would probably be done with TempZone Flex Rolls or TempZone Cable at 3" spacing. All heating is considered supplemental unless a heat loss calculation is done.
WarmlyYours’ 25-Year No Nonsense™ Warranty is the most comprehensive warranty in the industry. In the event of a defect, we cover not only the repair or replacement of the TempZone™ system, but ALSO any labor costs AND flooring materials required to perform the repair. We do not cover the cost of flooring that needs to be replaced in the event of a repair necessitated due to damage. If a product is damaged by a power surge, that would not be covered by our warranty
Yes. The WarmlyYours TempZone™ floor heating system has withstood rigorous safety testing by the Underwriter's Laboratory and has received UL listing for the U.S. as well cUL certification for Canada. WarmlyYours offers thermostats that carry the CSA Mark and the UL listing, which certifies that the product has been tested under extreme conditions and meets applicable standards for safety and/or performance in the U.S. and Canada. All WarmlyYours thermostats contain a Ground Fault Circuit Interrupter (GFCI) which provides fail-safe protection against an electrical shock.
This is stated in the Installation Manual of the LVT product when purchased. On average, this maximum temperature will fall between 80°F and 83°F. This number can then be used to program the thermostat during setup to set the floor's maximum temperature.
Yes, Luxury Vinyl Tile (LVT) is typically installed over the embedded heating element using self-leveling cement (SLC). Many people choose to use SLC when installing tile over floor heating.
We do not suggest using thinset to encase the heating wires with LVT, as it is very difficult to get thinset completely flat.
The TempZone™ twin conductor cable present in our TempZone™ products is comprised of a double-insulated, coaxial heating cable. The total thickness of the system can be between ⅛” and 5/32” thick and will not noticeably affect the height of your installed flooring. The heating system is encased in 3/8" of modified thinset or Self leveling underlayment. You simply use that 3/8" layer throughout the space, eliminating any need for fillers.
If the flooring manufacturer has a warranty for electric floor heating, it should not be adversely affected by shrinkage, expansion, or warping. Again, it will depend on the brand and construction of the product. Some manufacturers may place limitations on the maximum floor heating temperature. To minimize expansion and contraction, some Luxury Vinyl Tile companies require heating the flooring to a continuous heating level with "setback" temperatures (lower temperature settings during the day and overnight) kept to a minimum.
While radiant heating can affect the expansion and contraction of the floor, the most overlooked and important factor is the relative humidity in the space, so a humidifier or dehumidifier may be needed.
The actual cost of operating your floor heating system will vary depending upon a number of factors including the cost of electricity in your area and the length of time you run your system. The WarmlyYours TempZone™ Flex Roll electric floor heating system, for example, uses 15 watts per square foot. Based on a national average electricity rate of $.10/kW/hr, the approximate operating cost of an average bathroom using this system, measuring 8' x 10' would be between $.16 - $.21 cents a day. This cost is based on running your system a full 8 hours per day. Try our Operating Cost Calculator for a quick estimate.
No. Never cut the heating cable. The floor heating cable is designed with a very specific resistance in order to consistently maintain heating at the chosen wattage per square foot. Trimming the heating cable would lower the resistance of the cable causing the system to overheat. Adding heating cable to the system would raise the resistance and the system would not heat properly.
We suggest removing SPC or WPC flooring before installing the floor heating system over it if possible. If that is not practical, use an underlayment designed specifically for covering these types of floors. Radiant heating can be used with many types of these floors, but check with the flooring manufacturer to confirm that it can be paired with these types of systems.
TempZone™ is an electric floor heating system that operates like an electric blanket for your floors. TempZone™ is covered in thin-set or Self-Leveling Underlayment, and is installed over the top of your subfloor and beneath your flooring. The system provides a warm, even temperature across your floor, generating floor-to-ceiling radiant warmth to transform these naturally cold surfaces into warm floors. Ideal for kitchens, bathrooms or any room in your home where you would enjoy radiant warmth and comfort, the TempZone™ floor heating system is easy to install, operate and maintain.
LVT (Luxury Vinyl Tile), WPC (Wood Plastic Composite), and Solid Core all fall into the category of "vinyl flooring." These vinyl flooring types can be rated for floor heating, but the application will completely depend on the manufacturer's guidelines.
Please look in the installation manual and warranty documents of the LVT, WPC, and Solid Core flooring product that you are interested in to see if and what types of heating are allowed.
As for a list of manufacturers of LVT, WPC, and Solid Core products providing a warranty for their products with radiant heat -- many do provide a warranty for their products when properly installed with floor heating. The list of these is ever-changing, so please be sure to check with the flooring manufacturer for current recommendations.
The TempZone™ twin conductor cable present in our TempZone™ products is comprised of a double-insulated, coaxial heating cable. The total thickness of the system can be between ⅛” and 5/32” thick and will not noticeably affect the height of your installed flooring.
There are heating systems designed for floating floors, such as our Environ system. However, the flooring must be rigid enough so it does not mold itself to the heating cables over time.
Check the flooring manufacturer's floor heating recommendations. In most cases, the heating system will need to be embedded beneath the flooring. Check for all "flatness" requirements for the flooring you choose. The flattest floors utilize self-leveling cement when installed correctly.