Never cut the heating cable. A heating cable will not work if it has been cut. If the heating cable is too long, call WarmlyYours to consult with a technician who will guide you in utilizing the additional length of cable.
Need more help? View support options
When installing outdoor WarmlyYours snow melting cables for your driveway, patio, walkway, terrace, stairs, ramp, etc. - NEVER cross, overlap, or allow the heating cables to touch each other. Doing so will quickly cause a circuit failure due to excessive heat build up. Always follow the installation instructions and/or design layout plan to ensure the cable is installed with the correct spacing required for proper operation.
Need more help? View support options
This National Electric Code (NEC) required protection for fixed outdoor deicing and snow-melting equipment may be accomplished by using circuit breakers equipped with ground-fault equipment protection (GFEP) of 30 mA. It is important to understand that this required equipment protection is not the same as a 5 mA GFCI used for personal protection.
Need more help? View support options
If a cable is damaged during installation, recheck the system for continuity and confirm the integrity of the insulation with a megohmmeter, or "megger" tester, referring to the installation and testing instructions. If the cable fails any of these tests, take the following actions: clear a 3 foot square working area around the damaged section of cable, and record the cable part number from the UL tag and the location where you purchased the product. Call WarmlyYours with the above information. WarmlyYours will provide further assistance and supply a splice kit suitable for repairing the particular cable.
Need more help? View support options
The most common spacing for snow melting systems is 3“ from wire to wire. However, we can design snow melting systems based on your local climate and weather expectations that might have different cable spacings to ensure the most efficient system possible. We also offer snow melting mats with 3" and 4" spacing.
Need more help? View support options
In addition to showing the status of the snow/ice melting system and controlling the hold-on time, the RCO will turn on/off the heat for these controllers.
Note: When the Heater Cycle switch is momentarily depressed, it will start a manual Heater Cycle for the Cycle Time setting. Momentarily depressed while heaters are being operated by a Hold-On Timer or during manual Heater Cycle will end the Heater Cycle. Heater operation during snow conditions cannot be canceled in this manner.
Need more help? View support options
Length | 5.25″ |
Weight | 0.7 lbs |
Width | 7.25″ |
Maximum Distance from Controller | 500′ |
Voltage | 24 V |
Package Contents | RCU-3 Remote Control Unit (Qty 1), Wallplate Screws (Qty 2), 25′ Unshielded 22 Gauge 2-wire Jacketed Cable, Installation Manual |
SKU | RCO |
UPC (GTIN-12) | 881308021122 |
Warranty | 2 years |