How to Test Environ Products for Ohms, ohm testing

Share:


For 120V, Test yellow-to-black, yellow-to-ground, and black-to-ground. Verify proper ohms (within 10-15% of the value stated on the product label) across yellow-to-black, and no ohms for both yellow-to-ground and black-to-ground.

For 240V, Test red to black, red to ground, black to ground. Verify proper ohms (within 10-15% of the value stated on the product label) across red to black, and no ohms for both red to ground and black-to-ground.

For most products (under 200 ohms) set the DIGITAL, NON-SELF-RANGING meter to the 200 ohm range. Some heaters may require testing over 200 ohms, for these, set the meter to the 2000 (2k) range.

See instructions in attachment.

Written by Scott Rosenbaum
Posted on

Speak to a radiant heating expert