WSHC-120-00292 Frequently Asked Questions

Don't see the answer you're looking for? Post your question

While WarmlyYours electric radiant floor heating systems are typically installed by your floor covering contractor, a licensed electrician is recommended for the final thermostat hook-up. With every quote, we provide an Installation Plan layout, together with an electrical plan that has all the info required for the electrician.

35 people found this helpful.  Did you find this helpful? Yes No

You can use the Instant Quote Tool, which gives you many options for your floor heating coverage. Use this interactive tool to design your room online and receive an instant quotation with product recommendations, rough-in and installation kits, cost of your control, etc. Planning your floor heating project is made easy when using our Instant Quote Tool.

Send us your floor plan or fax it to (800) 408-1100 and we will send you a quote, product recommendation and a free custom installation plan for your project.

29 people found this helpful.  Did you find this helpful? Yes No

Our electric radiant floor heating systems have withstood rigorous safety testing and earned the UL listing. They produce much less EMF than common household appliances like your TV or vacuum cleaner. The EPRI (Electric Power Research Institute) tests all electrical devices and publishes the data. Many common household appliances are tested at a distance of 6 inches. The test results indicate that on average, the EMF emitted for the following appliances, measured in Milligauss (mG) units, is:

Vacuum Cleaner: 300 mG

Microwave: 200 mG

Portable Heater: 100 mG

Dishwasher: 20 mG

Washing Machine: 20 mG

WarmlyYours TempZone™ (Twin): 1.8 mG

28 people found this helpful.  Did you find this helpful? Yes No

WarmlyYours’ TempZone™ product is most commonly installed under tile, stone, and marble flooring, but can also be installed under many other popular floor covering options such as hardwood, vinyl and linoleum. We also have our Environ system, which is an electric floor heating product as well and is specially designed for installation under carpet (in the U.S. only), laminate and floating wood. WarmlyYours can accommodate any flooring type with either of the electric radiant floor heating products that we offer. If your flooring type isn't listed here, just give us a call at (800) 875-5285 and we will be happy to discuss it with you.

24 people found this helpful.  Did you find this helpful? Yes No

Yes. Unlike the heating cable for electric floor heating, the cold lead wires can be trimmed.

18 people found this helpful.  Did you find this helpful? Yes No

Sunrooms can be very cold during the winter months. While a furnace may push some warm air into the room, the large number of windows, exterior walls, and other causes of heat loss in a sunroom will typically keep it from having a comfortable temperature level. Floor heating and radiant panels will add radiant heat, which the human body absorbs faster than other forms of heat, to the room so that it feels warm even at lower temperatures.

17 people found this helpful.  Did you find this helpful? Yes No

Electric radiant floor heating should not be installed under permanent fixtures that may trap heat. However, if the vanity or cabinets are "floating" or are on legs, then a floor heating system may be installed under it.

14 people found this helpful.  Did you find this helpful? Yes No

Yes, but any furniture that may trap heat, such as pieces with an enclosed bottom, should be avoided. Furniture on legs with a clearance of at least 3" is permissible.

13 people found this helpful.  Did you find this helpful? Yes No

Please keep in mind that you must check your electric floor heating system with a digital ohmmeter in conjunction with a Circuit Check™. Take an initial reading as soon as you take the product out of the box to verify that it is within -5% / +10% of the values stated on the product’s label. This will give you a basis of comparison for future readings. Take a second reading once you have positioned the system to match your custom installation plan. It is also advisable to take an additional reading in the middle of the tile installation, just to make sure that the Circuit Check™ is doing its job. Then, take a final reading when you are finished with the floor installation and are ready to hook up the thermostat.

The Circuit Check™ is a tool developed by WarmlyYours to give you peace of mind and ensure trouble-free installations. Simply hook up the cold leads to the tool while you position the system to match your custom installation plan.

The Circuit Check™ will continuously monitor the continuity of the circuit during the installation of your system and during the installation of your flooring. The Circuit Check™ beeps immediately when a short in the system is detected, alerting you to a potentially damaged cable in the area you are working, before you lay the tile over the electric floor heating system.
 The WarmlyYours technical support team is available 24/7 to provide assistance if the alarm sounds, or if you would have any questions during your installation.

12 people found this helpful.  Did you find this helpful? Yes No

The answer to this question will depend on a whole host of variables related to electric floor heating, including, but not limited to, the run time (for supplemental heating, we usually recommend between 4-8 hours per day), the electric radiant floor heating system you're using, the total square footage, and your local electrical cost. Typically, the cost is just a few cents a day. 

To figure out how much electric floor heating might cost to run for you, make sure to use our interactive Operating Cost Calculator. 

11 people found this helpful.  Did you find this helpful? Yes No

Yes, the drying effects of electric radiant floor heating will reduce the humidity coming from the slab, which is the largest source of moisture.

9 people found this helpful.  Did you find this helpful? Yes No

No, it is recommended that floor heating only be installed in the areas that you will walk on. Heat can become trapped if installed under objects that do not offer enough clearance for air to circulate (such as a washer or dryer).

9 people found this helpful.  Did you find this helpful? Yes No

Electric-resistance heating cables and systems have no polarity. This includes all current WarmlyYours heating elements.

9 people found this helpful.  Did you find this helpful? Yes No

Yes, in most cases, an electric floor heating system can be effective as a primary heat source. However, our TempZone™ and Environ™ systems are most commonly used as a secondary heat source, providing floor-to-ceiling radiant heat to any room in your home where you desire more warmth and comfort.

If you are considering electric floor heating for an addition to your home, such as a sunroom where you have no other source of heat, WarmlyYours offers an innovative online tool which calculates approximate heat loss. This tool can help you to determine if a WarmlyYours’ electric radiant floor heating system will provide your desired comfort temperature throughout the year. You can access the Heat Loss Calculator or you can call us at (800) 875-5285 and a Customer Service Representative will make the calculation for you.

8 people found this helpful.  Did you find this helpful? Yes No

The amount of amperage draw depends upon how large the area is that you are heating. For coverage of areas less than 30 square feet, a 120V Slab Heat system will draw less than 6 amps. If you have a larger area over 180 square feet of heated space, then you will need a larger breaker plus additional controls. No matter what the size of the area you choose to heat, we recommend a dedicated circuit for your electric radiant floor heating system.

8 people found this helpful.  Did you find this helpful? Yes No

Since most Luxury Vinyl Tile (LVT) manufacturer's set a maximum temperature for radiant floor heating, the system should have little to no effect on the rubber/cork backing.

Pre-attached backing can act as an insulating layer though, meaning it can prevent the radiant heating from efficiently directing heat up through the floor. Please check with the manufacturer for the r-value of the product. Look for an assembled plank with an r-value of less than 1. The lower the r-value, the better!

8 people found this helpful.  Did you find this helpful? Yes No

Yes. While there are some floor heating systems that can be installed beneath floor joists, most electric radiant floor heating systems will need to be installed beneath the floor itself. This is why the best time to install electric floor heating is during a remodel or as a part of a new construction, when a floor is being installed anyways. 

If you're interested in alternative radiant heating methods, check out our Radiant Panels, which are wall-mounted and use infrared technology to provide supplemental heating. 

7 people found this helpful.  Did you find this helpful? Yes No

While both hydronic (heated water) and electric floor heating systems perform a similar function by providing radiant heat from beneath your floor, they do differ in some pretty crucial ways. Typically, using hot water instead of electricity will result in lower operational costs but significantly higher investment and maintenance costs. This usually means that hydronic heating systems are reserved for new construction projects (where it is easier to incorporate the boilers and pumps needed to operate the system) and electric floor heating is often used for remodeling projects in bathrooms, kitchens, etc. To learn more about the differences between these systems, check out this post. 

7 people found this helpful.  Did you find this helpful? Yes No

A typical bathroom floor can be heated for about a quarter a day with electric radiant floor heating.

7 people found this helpful.  Did you find this helpful? Yes No

Yes, our TempZone Heating Products can be used for heating luxury vinyl tile or luxury vinyl planks in any indoor application.

7 people found this helpful.  Did you find this helpful? Yes No

Supplemental heat can be addressed by changing the spacing on cable installs. Floor location in the house is very important when considering adding supplemental heating to a floor. For example: If heating a second story floor, over a heated space, cable at 4" spacing can be used. The same type of heating over an unheated space would probably be done with TempZone Flex Rolls or TempZone Cable at 3" spacing. All heating is considered supplemental unless a heat loss calculation is done.

7 people found this helpful.  Did you find this helpful? Yes No

A floor heating system can work as a supplemental heating source and make the basement warmer. If more heat needs to be added to the room, you can experiment with setting the floor heating thermostat to higher temperatures.

6 people found this helpful.  Did you find this helpful? Yes No

The breaker and wire sizes are selected based on the total amperage of the WarmlyYours heating system connected to a single thermostat. This information is on the WarmlyYours heating system's installation plan, electrical plan, or UL label. Based on guidelines from the National Electrical Code: loads up to 16 Amps may utilize 12 gauge wire with a 20-Amp breaker, and loads up to 12 Amps - 14 gauge wire with a 15-Amp breaker. Local code and/or other factors may change these guidelines.

6 people found this helpful.  Did you find this helpful? Yes No

Electric floor heating works by having an electric heating cable installed underneath the flooring (embedded or floating, depending on the system and floor type), which is then wired to a special thermostat (either one specifically designed for electric radiant floor heating, like a WarmlyYours’ nSpiration Series control, or a third-party thermostat). When turned on, the heating cable emits heat upward through the flooring which is then radiated throughout the room, heating all solid surfaces. 

5 people found this helpful.  Did you find this helpful? Yes No

The temperature of your floor can range anywhere between 75°F to 95°F. The floor's actual temperature will depend on a number of factors including the amount of heat loss that the room experiences as well as the room’s configuration. For instance, the warmth contained in a two story entry way would likely be less than that of a smaller, more enclosed area such as a bathroom. In a bathroom that is located on the second floor of your home or over another floor in your home that is typically heated, the temperature of your heated floor should easily reach a comfortable temperature of 85 degrees Fahrenheit, if the electric floor heating system is installed correctly. For the heat loss calculation for your specific room, you can access the Heat Loss Calculator or you can call us at (800) 875-5285 and a Customer Service Representative will make the calculation for you.

4 people found this helpful.  Did you find this helpful? Yes No

WarmlyYours nSpiration controls are equipped with an in-floor sensor to precisely control the floor's temperature to comply with the wood manufacturer's temperature recommendation.

4 people found this helpful.  Did you find this helpful? Yes No

This is stated in the Installation Manual of the LVT product when purchased. On average, this maximum temperature will fall between 80°F and 83°F. This number can then be used to program the thermostat during setup to set the floor's maximum temperature.

4 people found this helpful.  Did you find this helpful? Yes No

One thermostat can control multiple heating mats/cables as long as all the heating elements are using less than 15 amps:

TempZone™ will cover aprx. 120 sq. ft. for 120V systems and 240 sq. ft. for 240V systems on one thermostat.

Environ™ will cover aprx. 150 sq. ft. for 120V systems and 300 sq. ft. for 240V systems on one thermostat.

Slab Heat will cover aprx. 90 sq. ft. for 120V systems and 180 sq. ft. for 240V systems on one thermostat.

4 people found this helpful.  Did you find this helpful? Yes No

Floor heating will typically add the most heat to supplement an existing heating source and it will not take any extra space since it is embedded in the floor. If you are not remodeling your floors but have some open wall space, you should mount a radiant panel. For the most effective results, install the panel so that it points toward the area where you will spend most of the time.

3 people found this helpful.  Did you find this helpful? Yes No

Typically, electric floor heating is used as a supplemental heat source but in some cases, it can be used as a primary heat source. Electric floor heating is more energy efficient, less prone to spreading dust and allergens, and easier to control from room to room. Air-based heating systems can be used for both heating and cooling and can be a good way to control air quality in the home with regular maintenance. 

For a more in-depth answer to this question, check out Your ‘Cheat Sheet’ for Radiant Heat vs. Forced Air. 

3 people found this helpful.  Did you find this helpful? Yes No

If the flooring manufacturer has a warranty for electric floor heating, it should not be adversely affected by shrinkage, expansion, or warping. Again, it will depend on the brand and construction of the product. Some manufacturers may place limitations on the maximum floor heating temperature. To minimize expansion and contraction, some Luxury Vinyl Tile companies require heating the flooring to a continuous heating level with "setback" temperatures (lower temperature settings during the day and overnight) kept to a minimum.

While radiant heating can affect the expansion and contraction of the floor, the most overlooked and important factor is the relative humidity in the space, so a humidifier or dehumidifier may be needed.

3 people found this helpful.  Did you find this helpful? Yes No

For best results, we recommend a 1”- 1.5” maximum distance between the heating cable and the top of the floor. Nailed down hardwood will require sleepers to run the cable safely between board nails. Be sure to use 3/8" to 3/4" of self-leveling cement to embed the heating element.

3 people found this helpful.  Did you find this helpful? Yes No

No, most in-floor heating is designed to be added to new flooring. If you do have existing wood floors you would like to add radiant heating to - it is possible to do so with an under-joist heating system. 

3 people found this helpful.  Did you find this helpful? Yes No

Yes, with our programmable thermostats, you can choose which days and times the floor heating turns on for your comfort. With a Smart thermostat, you can also control these options from your phone while away from home.

2 people found this helpful.  Did you find this helpful? Yes No

LVT (Luxury Vinyl Tile), WPC (Wood Plastic Composite), and Solid Core all fall into the category of "vinyl flooring." These vinyl flooring types can be rated for floor heating, but the application will completely depend on the manufacturer's guidelines.
Please look in the installation manual and warranty documents of the LVT, WPC, and Solid Core flooring product that you are interested in to see if and what types of heating are allowed.

As for a list of manufacturers of LVT, WPC, and Solid Core products providing a warranty for their products with radiant heat -- many do provide a warranty for their products when properly installed with floor heating. The list of these is ever-changing, so please be sure to check with the flooring manufacturer for current recommendations.

2 people found this helpful.  Did you find this helpful? Yes No

Yes. In addition to TempZone™ and Slab Heat, we also have specially sized Shower and Bench mats designed specifically for shower installation. They are all wet location listed for radiant floor heating in a shower.

2 people found this helpful.  Did you find this helpful? Yes No

WarmlyYours has recently begun including floor sensors with our heating elements to help ensure customers will have everything they need for optimal operation of their radiant heating systems.

The sensor included with your floor heating element can be installed with the heating system (the sensor is equally spaced between runs of the heating wire--see your install manual for more info). Installing this sensor with your floor heating control will enable energy efficient operation of the floor warming system based on the floor temperature instead of the ambient room temperature.

We generally recommend that you install a second, unconnected backup floor sensor alongside the primary one. In the very unlikely event that your first floor sensor is damaged, this install method will save you from having to pry up flooring to replace a floor sensor. You simply disconnect the damaged sensor from the thermostat and connect the backup sensor.

In addition to the floor sensor that was included with your heating element, our nSpiration Series thermostats also come with a floor sensor. If you purchase both a heating element and an nSpiration Series thermostat from WarmlyYours, you'll have a primary and a backup floor sensor for your system.

2 people found this helpful.  Did you find this helpful? Yes No

Cork flooring can be used with floor heating if the r-value is under 1. You will need to find the r-value of the flooring you choose and let your account manager know during the design stage. Cork flooring should have a low r-value to minimize trapped heat.

2 people found this helpful.  Did you find this helpful? Yes No

Yes, sunrooms can be used in the winter, just activate your floor heating or radiant panel and turn your sunroom into a 4-season room. You will notice a tremendous difference in the room comfort, especially with the thermostat set to maintain a desired ambient temperature. WarmlyYours thermostats will do the work for you by energizing the floor for longer cycles.

1 person found this helpful.  Did you find this helpful? Yes No

Everyone has their own comfortable temperature setting, but we typically find that our customers use their thermostats to set the "floor temperature" of the system in the 78°F - 84°F range.

1 person found this helpful.  Did you find this helpful? Yes No

The requirements are determined as follows: plan on 20 watts per square foot (at 3" spacing) without a floor covering; or 15 watts per square foot (at 5" spacing, cable only) with a floor covering. To calculate approximate power requirements, multiply the square feet by either 20 or 15 (per the above), and then divide by the voltage (120V or 240V) to arrive at Amps.

1 person found this helpful.  Did you find this helpful? Yes No

The cost for the heating elements in a Slab Heating system is $7 per sq. ft. ($8 CAD) for Slab Heating Mats and $7 per sq. ft. ($9 CAD) for Slab Heating Cables.

1 person found this helpful.  Did you find this helpful? Yes No

We usually recommend that you have an individual thermostat for each room. However, if it's an open floor plan and your local electrical code allows you to have one controller for the whole area, then it's definitely possible to have it all controlled from one thermostat.

1 person found this helpful.  Did you find this helpful? Yes No

We recommend verifying 3 things with the manufacturer of the flooring product to be heated;

1.) Is the flooring product compatible with electric floor heating?

2.) What is the maximum temperature the flooring product can withstand?

3.) What is the temperature set back recommendation of the flooring product?

1 person found this helpful.  Did you find this helpful? Yes No

You can control your slab heating system with any WarmlyYours nSpiration Series thermostat. Depending on the size of your project, you may also need to add a relay or nJoin power module.

Did you find this helpful? Yes No

In-stock items will ship the same day if you place your order before 4:00 PM CST.

Did you find this helpful? Yes No

Stop installation, box out a 3"×3" area surrounding the damaged area, and call tech support at (800) 875-5285.

Did you find this helpful? Yes No

Any trade professional is qualified to layout slab heating cables and/or mats; electricians must make the electrical connections and test the wire; you can hire a concrete contractor to install the concrete for you.

Did you find this helpful? Yes No

The Slab Heat radiant system adds no additional height. This is because it is embedded within the concrete pour.

Did you find this helpful? Yes No

Yes, you can install multiple sensors while installing the floor heating system. Only one of these sensors should be connected to the floor heating thermostat. Any secondary sensors can be run through conduit up to the thermostat area to be connected in the future should anything happen to the original sensor. The sensor is low voltage and may not need conduit. If conduit is required, it will need to be separate from the return power leads.

Did you find this helpful? Yes No

Please refer to our Dealer/Installer Locator.  We will connect you to the best dealer/installer in your area.

Did you find this helpful? Yes No

A Warmly Yours indoor floor heating system should not be installed with a GFCI breaker because GFCI protection is built into the thermostat and power module.  And while it's not always required, we strongly recommend a dedicated circuit for each thermostat and power module to limit the occurrence of ground fault nuisance tripping caused by multiple GFCI devices on a circuit. The amperage of a breaker would depend on the amp draw of the heating system. For example, a TempZone Flex Roll (which provides approximately 15 watts of energy output per square foot) that is providing 15 square feet of heating coverage will draw only 225 watts ( 1.9 Amps), so a 15 Amp circuit would suffice.  Always size breakers according to your local Electrical Code requirements. 

Did you find this helpful? Yes No

An area where large furniture will cover the floor should have enough clearance underneath to allow air to circulate. Any areas where floor heat may be trapped (rugs, box bottom furniture), let your sales rep know so we can design an installation plan around these areas.

Did you find this helpful? Yes No

The layers for the full installation are as follows:

  • Bottom: 8-10" of compressed crushed rock aggregate (may already exist)
  • 2" polystyrene insulation
  • 2-3" layer of concrete
  • Rebar and/or reinforcing mesh and attach the cable or mat
  • Top: Pour a 2-3" layer of concrete as the final flooring surface

Call tech support at +1 (800) 875-5285 to customize this to your unique application.

Did you find this helpful? Yes No

Hydronic systems operate by using heated water pumped through tubing beneath the floor. Electric underfloor heating works with heated cables beneath the floor. Typically, hydronic systems are a good choice for new construction projects and electric systems are better for remodels or single rooms. This is because the high installation costs of hydronic systems (boilers, pumps, etc.) makes them cost-prohibitive for projects like a bathroom or kitchen. Electric radiant heating systems are also easier to repair than hydronic systems if they're damaged. 

For a more complete answer to this question, check out this blogpost. 

Did you find this helpful? Yes No

You should install the cable 2-3" below the finished surface, and attach it to rebar and/or reinforcing wire mesh to secure the cable in place.

Did you find this helpful? Yes No

The ground wire in the floor mat must be connected directly to the ground wire of the supply or to the house ground wire.

Did you find this helpful? Yes No

There is a way to install floor heating that makes it suitable for any type of floor. By embedding our TempZone systems in self-leveling cement (SLC), you have created a heated subfloor. Almost any low r-value flooring can be installed directly over this for heated floors.

Did you find this helpful? Yes No

No. A bathroom floor would be installed in the same way. Our Slab Heat floor heating systems are wet-location listed and great for bathroom floors.

Did you find this helpful? Yes No